Contact the CFRL  
   

High Pressure Spray Test Rig

The high pressure spray test rig is used to test liquid jets and sheet breakup at elevated pressures and temperatures. The facility can obtain spray penetration and fuel distribution data.

Facility Features

  • Static Pressure: 150 psig
  • Air Flow Rate: 1.5 lb/sec
  • Air Heater: 192 kW
  • Temperature: 900°F
  • Test Section: 1x1.25”
  • Traverse control: 3D, fully-automated
  • Multi-channel DAQ
  • Diagnostics: Background shadowgraphy, PLIF

 




Copyright Information © 2015 University of Cincinnati
College of Engineering & Applied Science | Department of Aerospace Engineering & Engineering Mechanics